TxIsoRail-HRT Temperature Transmitter

Features:

✔  Input Types: Supports Thermocouples (J, K, T, N, R, S, B, E), RTDs (Pt100, Pt1000), NTC thermistors, and voltage inputs (0-50 mV).

✔  Output Type: 4-20 mA current loop

✔  Output Resolution: 0.25 µA

✔  Thermal Drift: < 0.05% per 25 °C (77 °F)

✔  Isolation (Input-Output): 1.5 kVrms

✔  Electrical Protection: Reverse polarity protection

✔  HART® Version: HART V7, compatible with HART V5

The resilience of NOVUS devices and the established quality of HART® certification are combined in the temperature transmitter TxIsoRail-HRT. The transmitter supports voltage spikes up to 1.5 kVrms and offers electrical isolation between input and output. It is compatible with devices that have earned the HART® certification. The main difference is that it has two 4-20 mA current loop wires for total configuration, which means more functionality for monitoring and device setting.
NOVUS’s temperature transmitter TxIsoRail-HRT uses a globally recognized protocol with over 40 million field instruments that accept HART® technology.

Description

TxIsoRail-HRT Temperature Transmitter

The TxIsoRail-HRT temperature transmitter by NOVUS combines the proven reliability of NOVUS hardware with the advanced communication capabilities of the HART® protocol. Designed for industrial applications, it supports universal sensor inputs including thermocouples (J, K, T, N, R, S, B, E), RTDs (Pt100, Pt1000), NTC thermistors, and low voltage signals (0-50 mV).

Key features include:

  • HART® Certification: Supports HART V7 and is backward compatible with HART V5, enabling two-way digital communication over the standard 4-20 mA current loop for remote configuration, diagnostics, and monitoring.

  • Electrical Isolation: Provides 1.5 kVrms isolation between input and output, protecting the system against voltage surges and ensuring signal integrity.

  • High Accuracy: Typical accuracy ranges from 0.07% to 0.2% of span depending on sensor type, with low thermal drift (<0.05% per 25 °C).

  • Robust Design: Operates reliably in harsh environments with a temperature range of -40 to 85 °C and up to 90% relative humidity.

  • DIN Rail Mounting: Compact design for easy installation on standard 35 mm DIN rails.

  • Power Supply: Loop powered (8.5 to 36 Vdc), simplifying wiring and reducing installation costs.

  • Comprehensive Compliance: CE, NAMUR NE43, RoHS, REACH, and electromagnetic compatibility standards ensure suitability for industrial environments.

  • Configuration: Can be configured via TxConfig-HRT adapter or any HART-certified handheld device using TxConfigII software.

Technical Data

Technical Data

Technical Specifications

Part Code

8808016100

Input Type

J, K, T, N, R, S, B, E, Pt100, Pt1000, NTC and 0-50 mV

Accuracy Typical

Pt1000 / mV: 0.07 % span, Pt100: 0.08 % span, T/C: 0.07 % span ±1 °C (1.8 °F), NTC: 0.2 °C (0.36 °F)

Maximum

Pt1000 / mV: 0.15 % span , Pt100: 0.15 % span , T/C: 0.15 % span ±1 °C (1.8 °F) , NTC: 0.45 °C (0.81 °F)"

Output Type

4-20 mA

Output Resolution

0.25 µA

Thermal Drift

< 0.05 % / 25 °C (77 °F)

Isolation Input-Output

1.5 kVrms

Electric Protection

Reverse Polarity

HART® Version

HART V7, compatible with HART V5

Configuration Interface

Through TxConfig-HRT adapter or HART® certified HandHeld

Configuration Software

TxConfig II

Approvals / Regulations

CE, NAMUR NE43, RoHS, Reach, HART®

Operating Conditions

-40 to 85 °C (-40 to 185 °F) | 0 to 90% RH

Power Supply

4-20 mA Loop Powered (8.5 - 36 Vdc)

Enclosure

ABS UL94-HB

Format / Mounting

35 mm (TS35) DIN Rail

APPLICATIONS

APPLICATIONS

TxIsoRail-HRT Temperature Transmitter

The TxIsoRail-HRT temperature transmitter is ideal for industrial and process automation applications requiring precise, reliable, and isolated temperature measurement combined with smart communication capabilities. Key applications include:

  • Industrial Process Control: Accurate temperature monitoring and control in chemical, pharmaceutical, and food industries to ensure product quality and safety.

  • Power and Energy Sector: Modernization and digitalization of electric power utilities and smart grids, where robust and isolated temperature measurement is critical.

  • Harsh Industrial Environments: Suitable for environments with electrical noise and voltage surges due to its 1.5 kVrms input-output isolation and electromagnetic compatibility.

  • Smart Field Instrumentation: Enables remote configuration, diagnostics, and monitoring via the HART® protocol, improving maintenance and operational efficiency.

  • Automation Systems: Integration with control systems requiring standardized communication and reliable temperature data for process optimization.

Downloads

Downloads

Product Brochures
Technical-Manual- TxIsoRail-HRT Temperature Transmitter

 

Supply/ Delivery Scope

Supply/ Delivery Scope

  • TxIsoRail-HRT temperature transmitter, DIN rail mounted

  • User manual and technical documentation