Txisoloop-1 & Txisoloop-2
Features:
✔ High Isolation Protection – Eliminates ground loops and electrical noise.
✔ Loop-Powered Operation – No external power supply required
✔ Compact & Easy Installation – DIN-rail mountable design.
✔ Low Power Consumption – Minimal impact on loop power.
✔ Two Model Variants
– TxIsoLoop-1 – Single-channel isolation.
– TxIsoLoop-2 – Dual-channel isolation.
✔ Enhanced Signal Integrity – Accurate 4-20mA transmission.
✔ Robust Industrial Design – High EMC immunity.
Efficiency is not the main reason for automation. It also entails the necessity of extending the operation’s lifespan and security. Reducing measurement mistakes in electrical potential difference-prone systems involves safeguarding personnel and equipment from potential harm.
Txisoloop-1 & Txisoloop-2
Loop-powered Current Isolators Txisoloop-1 & Txisoloop-2
Efficiency is not the main reason for automation. It also entails the necessity of extending the operation’s lifespan and security. Reducing measurement mistakes in electrical potential difference-prone systems involves safeguarding personnel and equipment from potential harm.
NOVUS TxIsoLoop-1 and TxIsoLoop-2 offer single and dual loop galvanic isolation, making your application simpler and preventing unwanted ground loops. An identical isolated signal is replicated at the output once the 0/4-20 mA input is detected. There is no requirement for an external power source or auxiliary power because power is obtained from the 0(4)-20 mA input loop.
The TxIsoLoop galvanic isolator, which removes ground loops and works on up to two isolated channels, is advised for electrical grids where electric potential differences pose a significant risk. This ensures accuracy and signal safety.
The isolation eliminates the need for a separate power source by utilizing the TxIsoLoop from NOVUS. The output current is actively produced by the energy gained from the electric current flowing through the isolator input. With a response time of just 2 ms, this accessory is essential for industrial settings like petrochemicals or the manufacturing of sugar and alcohol.
By electrically separating the input signal from the output, loop isolators offer signal protection.
TxIsoLoop-1 and TxIsoLoop-2 offer single and dual loop galvanic isolation, making your application simpler and preventing unwanted ground loops. After measuring the 0/4-20 mA input, the output reproduces the same isolated signal. Since the 0(4)-20 mA input loop provides electricity, no external power source or auxiliary power is required.
Technical Data
Technical Specifications
Part Code
8813020100 / 8813020200
Input signal
0(4) to 20 mA (Check minimum current for proper operation)
Voltage drop − Input/output without protection (Vdrop)
< 3 Vdc
Voltage drop − Input/output with protection (Vdrop)
< 5 Vdc
Output signal
0(4) to 20 mA
Max. load (RL)
1450 R
Total accuracy
0.2 % @ 0 to 60 °C / RL = 250 R
0.3 % @ -20 to 75 °C / RL = 250 RMinimum operating current
> 0.1 mA
Maximum input current
< 40 mA
Response time
2 ms @ RL= 250 R
Current limit
31 mA
Electrical isolation
3000 Vac / 10 seconds
240 Vac continuousEMC
EN 61326-1 (without performance degradation)
Work environment
Temperature: -20 to 75 °C
Relative humidity: 20 to 90 %Housing
ABS (60 %) + PC (40 %)
Protection index
IP40
Wire gauge for connections
0.14 a 1.5 mm²
Recommended torque
0.8 Nm
Terminal enclosure
Polyamide
APPLICATIONS
-
Industrial Automation Systems:
Eliminate ground loops and ensure accurate signal transmission in automated production lines. -
Petrochemical Plants:
Protect sensitive measurement and control instruments in areas with high electrical noise and potential differences. -
Sugar and Alcohol Processing Industries:
Safeguard process signals against electrical disturbances for reliable monitoring and control. -
Water and Wastewater Treatment Plants:
Improve measurement reliability in large, distributed installations with varying electrical potentials. -
Oil & Gas Refineries:
Enhance safety and signal integrity in hazardous environments prone to grounding issues. -
Energy and Power Distribution Networks:
Isolate measurement signals in substations and power plants to prevent equipment damage. -
Building Automation Systems:
Provide safe signal separation and eliminate interferences in smart building applications. -
Chemical Processing Plants:
Maintain precise signal control and prevent costly signal distortions in aggressive industrial environments. -
OEM Equipment Manufacturing:
Integrate galvanic isolation for safer and more reliable instrumentation in custom-built industrial machinery.
Supply/ Delivery Scope
-
TxIsoLoop-1 or TxIsoLoop-2 Unit — Fully tested and ready for installation
-
Quick Start Guide / User Manual — For easy setup and operation
-
Factory Calibration Certificate — Ensuring performance and quality standards
-
Protective Packaging — Designed to prevent damage during transportation