Conductivity Controller-AQUIS Touch S
Make: JUMO (Made in Germany)
Model Code: AQUIS touch S
Part Code: AQUIS touch S
Order Code: KLSJMAQUIStouchS
Modular Multichannel Measuring Device for Liquid Analysis with Integrated Controller and Paperless Recorder
Features:
✔ Up to four analysis inputs in any combination for direct connection of sensors for liquid analysis
✔ Up to 21 further measuring signals can be connected either directly or via interface
✔ Two pulse frequency inputs for flow measurement (up to 300 Hz or 10 kHz)
✔ Up to 17 switching outputs that are configurable as controller outputs, switch outputs, and alarm outputs
✔ Interfaces: USB host, USB device, Modbus, PROFIBUS DP, Ethernet
✔ Ethernet function: web server, alarm alerts by email, setup per PC, readout of recorded measurement data
✔ Math and logic functions
✔ Integrated timers, washtimers, and calibration timers
✔ Service and operation hours counters
SKU: KLSJMAQUIStouchS
Brand Category: JUMO (Germany)
Product Category: Liquid Analysis
Warranty: 1 Years (against manufacturing defects only)
Conductivity Controller JUMO AQUIS touch S
Measurement
Whether it’s to display and process the pH value, redox voltage, electrolytic conductivity, high-purity water resistance, temperature, disinfection-related measurands (such as free chlorine, total chlorine, chlorine dioxide, ozone, hydrogen peroxide, and peracetic acid), or the flow volume, the JUMO AQUIS touch S Conductivity Controller provides a central platform to do so. For flow measurement, pulse frequency inputs (counters) are available. Using standard signals (4 to 20 mA or 0 to 10 V), universal inputs can be used to measure nearly any analogue measurand. Up to 19 parameters can be measured and managed at the same time by the unit.
Control
In addition to several simple alarm/limit-value/time-controlled switching capabilities, the JUMO AQUIS touch S allows for the simultaneous definition of up to four high-quality control loops.
In these applications, tried-and-true JUMO control algorithms are employed for P, PI, PD, and PID control.
Display
The display of all parameters, as well as the operation and setup of the device, is handled by a 5.5″ colour touch screen. The operation philosophy of simple text almost eliminates the necessity for a manual. The device’s operating language can be chosen from a list of 15 languages that were pre-installed at the factory. The PC setup programme can expand the language library to up to 30 languages. Languages that employ Chinese and Cyrillic characters can also be displayed. As a result, the device is poised for widespread adoption.
Recording
For data recording, a paperless recorder is included. It is possible to register up to eight analogue measurands and six binary signals. On the screen, their chronological order is shown. Data storage is impenetrable to tampering and complies with official record-keeping regulations. The data can be extracted using the JUMO PCC software or a USB flash drive, and then analysed using the JUMO PCA3000 PC evaluation programme.
.
Technical Data
Impedance measurement can optionally be activated.Inputs
Principal input
Measurement/control range
Accuracy
Temperature error
PH
-1 to +15 pH
≤ 0.3 %
0.2 %/10 K
ORP
-1500 to +1500 mV
≤ 0.3 %
0.2 %/10 K
NH3 (ammonia)
0 to 9999 ppm
≤ 0.3 %
0.2 %/10 K
Secondary input
Temperature
Pt100/1000
(automatic detection)
-50 to +250 °Ca
≤ 0.5 °C
0.05 %/10 K
Temperature
NTC/PTC
4 kΩ max.
Entry via table
with 20 value pairs
≤ 0.3 %b
0.05 %/10 K
Temperature compensation
Measurement variable
Compensation
Range
PH
Yes
-30 to +150 °C (as of software version 212.11.02)
& -10 to +150 °C (up to software version 212.11.01)
ORP
No
not applicable
NH3 (ammonia)
Yes
-20 to +50 °C
pH antimony
Yes
-10 to +80 °C
Measuring circuit monitoring
Inputs
Over/underrange
Short-circuit
Cable break
PH
Yes
Yes
Yes
ORP
Yes
No
No
NH3 (ammonia)
Yes
No
No
Temperature
Yes
Yes
Yes
Impedance measurement
Since it depends on some marginal parameters, the following points must be noted:
• Only glass-based sensors are permissible.
• The sensors must be directly connected to the transmitter.
It is not permissible to use an impedance converter in the measuring circuit.
• The maximum permissible cable length between sensor and transmitter is 10 m.
• Liquid impedances will directly influence the measurement result.
We therefore recommend activating the measurement in liquids from about 100 µS/cm upwards
Applications
- Municipal and industrial water treatment in wastewater treatment plants
- Process systems
- Drinking and bathing water monitoring
- Pharmaceutical water
- Food and beverage production (SIP/CIP plants)
- Gas scrubbers/air washers
- Cooling tower control
- Ion exchangers
- RO units (reverse osmosis)
- Power stations and energy plants
- Fish breeding
- Desalination of seawater
Downloads
Product Brochures
➤ Datasheet Controller JUMO AQUIS touch S (202581) (application/pdf, 308 KB)
Manuals
➤ Instructional Manual Controller JUMO AQUIS touch S (202581) (PDF, 1.8 MB)