Conductivity Transmitter-CombiLyz AFI4
Make: BAUMER (Made in Denmark)
Model Code: CombiLyz AFI4
Part Code: AFI4
Order Code: KLSTE091AFI4
Quick and easy device configuration and safe process monitoring Graphic display with individually adjustable display and multicolor traffic light system
Features:
✔ All-in-One conductivity sensor
✔ All wetted parts in PEEK
✔ Compact, food-safe, hygienic design
✔ 3-A sanitary standards and FDA-compliant, EHEDG-certified
✔ Available with HART® communication protocol
✔ Available with IO-Link communication interface
SKU:KLSTE091AFI4
Brand Category: BAUMER (Denmark)
Product Category: Conductivity Measurement
Warranty: 1 Years (against manufacturing defects only
Conductivity Transmitter-Baumer CombiLyz AFI4
Precise analysis and exact differentiation of fluid media
- Analog output of either conductivity or concentration
- Large touchscreen with varied presentation of process variables
- Short reaction time and fast temperature condensation
- Integrated programmable switching output
- Hygienic and durable one-piece design
- Digital integration by communication interface
The Conductivity Transmitter-Baumer CombiLyz AFI4 Transmitter is a high-performance instrument designed to deliver accurate and reliable conductivity measurements across a wide range of industrial applications. With its robust design, intuitive operation, and advanced technology, it is an ideal choice for industries like food & beverage, pharmaceuticals, water treatment, and more.
Key Features:
- High Precision: Exceptional accuracy in measuring conductivity and temperature, ensuring process efficiency and product quality.
- Versatile Measurement Range: Wide conductivity and temperature range, making it suitable for various process requirements.
- Hygienic Design: Fully compliant with industry hygiene standards, including EHEDG and FDA-approved materials.
- User-Friendly Interface: Intuitive touchscreen display for real-time monitoring and easy configuration.
- Robust Construction: Built to withstand harsh environments with high resistance to chemicals and mechanical stress.
- Customizable Outputs: Supports analog and digital output signals, including IO-Link, for seamless integration with automation systems.
Applications:
- Food & Beverage: Precise monitoring of CIP processes, dairy production, and beverage quality.
- Pharmaceuticals: Ensuring consistent product quality and compliance with regulatory standards.
- Water Treatment: Accurate conductivity measurement for desalination, filtration, and purification systems.
- Chemical Processing: Robust performance in corrosive environments for chemical concentration analysis.
Approvals:
Technical Data
Performance characteristics conductivity
Conductivity
14 selectable ranges
Min. measurable conductivity
50 µS/cm
Max. measuring span
1000 mS/cm
Min. measuring span
500 µS/cm
Max. measuring error
± 1.0 % FSR , 0 … 1 mS/cm to 0 … 500 mS/cm
± 1.5 % FSR , 0 … 1000 mS/cm
± 1.5 % FSR , 0 … 500 µS/cm
Reference temperature
25 °C , adjustable
Compensated temperature range
-20 … 150 °C
Repeatability
1 mS/cm
Temperature compensation
0.0 … 5.0 % FSR/K , adjustable
Step response time
≤ 2.0 s
Sample time
≤ 0.4 s
Performance characteristics concentration
Concentration
4 factory set media
Customer defined media
Customer defined (30 point lookup table)
Performance characteristics temperature
Measuring range
-20 … 150 °C
Temperature
Free programmable range
Thermal response time, T90
≤ 15 s
Max. measuring error
± 0.4 K
Process conditions
Process temperature
-20 … 140 °C , permanent
140 … 150 °C , max. t < 1 h
Process pressure
≤ 25 bar
Process connection
Connection variants
G 1 A hygienic
Wetted parts material
PEEK Natura
Surface roughness wetted parts
Ra ≤ 0.8 µm
HART® interface
Properties
Universal commands
Common-practice commands
Conductivity device family commands
Device Specific Commands
For more information please see ‚HART Field Device Specification‘
Protocol
HCF standard, Rev.7
IO-Link interface
IO-Link version
1.1
Device profile
Smart Sensor Profile
Baud rate
38,4 kbaud (COM2)
Cycle time
≥ 8.4 ms
Process data length
128 bit
SIO-mode
Yes
Process data (cyclic)
Switch state
Signal analog output 1
Signal analog output 2
Temperature
Unit temperature
Conductivity
Concentration
Actual measuring range
Ambient conditions
Degree of protection (EN 60529)
IP67
IP69K , with appropriate cable
Compliance and approvals
EMC
EN 61326-1
Hygiene
3-A (74-07)
EHEDG EL Class I
FDA (21 CFR 177.2415)
Safety
cULus listed, E491206
Downloads
Product Brochures
➤ Datasheet Baumer Conductivity Transmitter (application/pdf, 308 KB)